The ALTAIR Pro Detector uses highly accurate electrochemical sensors to measure concentrations of toxic gas (ammonia, carbon monoxide, chlorine, hydrogen cyanide, hydrogen sulfide, nitrogen dioxide, phosphine and sulfur dioxide) or percent oxygen depending on instrument version. This measurement is clearly displayed on the instrument's LCD. The detector is fast-responding and has clear alarm functions to alert the wearer. The sensors and battery can easily be replaced to keep the unit performing for years.
The ALTAIR Pro Detector automatically records the last 50 alarm or test events and has active data-logging. To read data or change alarm set points simply connect the unit to an MSA infrared adapter using the built-in IR communication port. A distinct alarm is indicated by two bright flashing LEDs, a piercing audible alarm, a flashing notification on the LCD, and an internal vibrating alarm, helping to ensure that no alarm condition will go by unnoticed. Its rubberized armor housing and one-button operation provide the durability and simplicity you expect.
• Ease-of-use (1-button operation) • Distinctive alarm system • Alarm check, bump check, fresh air zero, and calibration made easy • Easily-replaceable, commercially-available battery • Replaceable sensors • Built-in IR communication (event & data-logging) • Rugged design • Water- and dust-resistance
Spec Summary:
Size:
3.4”L x 2.0”W x 1.0”H
Weight:
4.0 oz including clip
Case Material:
Polycarbonate with rubber overmolding
Event Log:
Equipped with standard event data logging of no less than 50 events before overwriting oldest logged events
Data Log:
Equipped with standard data logging feature
Environmental Protection:
Rated to IP 67 protection levels for dust/water ingress
Alarms:
Equipped with visual, vibrating and audible alarms.
Audible alarms sound at an average of 95 dB @ 1 foot.
Visual alarms are bright and viewable from top, front and sides.
Bump Test:
A checkmark is displayed to indicate a successful bump test for 24 hours after conducting the bump test.
Operating Lifetime:
Typical installed battery life 9000 hours. Sensor life is two years.
Confidence Flash:
Unit periodically (average every 60 seconds) confirms proper operation by: Confidence flash on Alarm LEDs; Confidence dot on display (heartbeat indicator)
Backlight:
Activated at the start of any alarm situation or by a simple press of a button
Monitoring:
Range:
Ammonia (NH3) 0-100 ppm
Resolution:
1 ppm
Standard Alarm Points:
Low:
25 ppm
High:
50 ppm
Battery:
Replaceable CR2 lithium battery. Only Energizer EL1CR2, Varta CR2, or Panasonic CR2 batteries should be used
Calibration:
Zeroes and calibrated easily using one button
Calibration Set Point:
Calibration gas concentration set points are user-adjustable
Data Storage Capacity:
50 past events
Record Content:
Event log entries shall contain as a minimum Alarm: type, value, time and date Alarm clear: type, value, time and date Calibration: pass/fail, time and date Bump: pass/fail, time and date Error non-shutdown: error type, time and date End of life: reason, alarm minutes, months life, time and date
Datalogging:
Equipped with datalogging function. Default setting is three minute peak readings. This sample rate is configurable via PC 15 seconds to 15 minute peaks or one minute peak average.
Certifications:
US and Canada Class 1, Division 1, Groups A, B, C and D
Environmental:
Temperature:
Normal Operation: -20 to 50 °C
Humidity:
10-95% RH non-condensing
Maintenance:
Replaceable sensors and battery
Warranty:
Full two-year warranty. Does not cover battery
About Us
Electrical
Environmental
Material Testing
Water Quality
Resources
Bosworth Instrument 1995 E. 55th St. Cleveland, OH 44103 | 800-804-6218 | info@bosworthsupply.com