The ALTAIR Pro Remote Oxygen Detector-(O2-R) is a unique design in the safety industry. This O2 sensor is attached remotely at the end of a ten-foot cable, rather than inside the intrument's casing. This design allows the user to lower he sensor into a remote location and monitor the O2 level from 10 feet away.
The ALTAIR Pro Detector automatically records the last 50 alarm or test events and has active data-logging. To read data or change alarm set points simply connect the unit to an MSA infrared adapter using the built-in IR communication port. A distinct alarm is indicated by two bright flashing LEDs, a piercing audible alarm, a flashing notification on the LCD, and an internal vibrating alarm, helping to ensure that no alarm condition will go by unnoticed. Its rubberized armor housing and one-button operation provide the durability and simplicity you expect.
• Ease-of-use (1-button operation) • Distinctive alarm system • Alarm check, bump check, fresh air zero, and calibration made easy • Easily-replaceable, commercially-available battery • Replaceable sensors • Built-in IR communication (event & data-logging) • Rugged design • Water- and dust-resistance
Spec Summary:
Size:
3.4”L x 2.0”W x 1.0”H
Weight:
4.0 oz including clip
Case Material:
Polycarbonate with rubber overmolding
Event Log:
Equipped with standard event data logging of no less than 50 events before overwriting oldest logged events
Data Log:
Equipped with standard data logging feature
Environmental Protection:
Rated to IP 67 protection levels for dust/water ingress
Alarms:
Equipped with visual, vibrating and audible alarms.
Audible alarms sound at an average of 95 dB @ 1 foot.
Visual alarms are bright and viewable from top, front and sides.
Bump Test:
A checkmark is displayed to indicate a successful bump test for 24 hours after conducting the bump test.
Operating Lifetime:
Typical installed battery life 9000 hours. Sensor life is two years.
Confidence Flash:
Unit periodically (average every 60 seconds) confirms proper operation by: Confidence flash on Alarm LEDs; Confidence dot on display (heartbeat indicator)
Backlight:
Activated at the start of any alarm situation or by a simple press of a button
Monitoring:
Range:
0-25% by vol.
Resolution:
0.1 Vol.%
Standard Alarm Points:
Low:
19.50%
High:
23.00%
Battery:
Replaceable CR2 lithium battery. Only Energizer EL1CR2, Varta CR2, or Panasonic CR2 batteries should be used
Calibration:
Zeroes and calibrated easily using one button
Calibration Set Point:
Calibration gas concentration set points are user-adjustable
Data Storage Capacity:
50 past events
Record Content:
Event log entries shall contain as a minimum Alarm: type, value, time and date Alarm clear: type, value, time and date Calibration: pass/fail, time and date Bump: pass/fail, time and date Error non-shutdown: error type, time and date End of life: reason, alarm minutes, months life, time and date
Datalogging:
Equipped with datalogging function. Default setting is three minute peak readings. This sample rate is configurable via PC 15 seconds to 15 minute peaks or one minute peak average.
Certifications:
US and Canada Class 1, Division 1, Groups A, B, C and D
Environmental:
Temperature:
Normal Operation: -20 to 50 °C
Humidity:
10-95% RH non-condensing
Maintenance:
Replaceable sensors and battery
Warranty:
Full two-year warranty. Does not cover battery